Carrier 42PHQ018N Manual de instalación

Busca en linea o descarga Manual de instalación para Acondicionadores de aire del sistema de división Carrier 42PHQ018N. Carrier 42PHQ018N Installation manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
42PHQ---N
INSTALLATION MANUAL
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - 42PHQ---N

42PHQ---NINSTALLATION MANUAL

Pagina 2

GB - 942PHQ---NENGLISHCheck• Next, check the unit drain system by pouring some water intothe unit drain pan and ensuring that it flows freely through

Pagina 3

GB - 1042PHQ---NIndoor unit wiring• Lift the front panel up to the top of the unit; in this way the frontpanel will be separated from the unit.• Remo

Pagina 4

GB - 1142PHQ---NENGLISHElectrical connectionCooling only (42PHQ018, 024N)Minimum connection wire sizebetween indoor and outdoor (mm2)Model GND L N N

Pagina 5

GB - 1242PHQ---N21Minimum connection Minimum connection wire sizewire size (mm2) between indoor and outdoor (mm2)Model GND L N N Y O W242PHQ 007N, 00

Pagina 6

GB - 1342PHQ---NENGLISHThe General Information For Multi or T-kit modelThe configuration setting by remote controller• Entering Configuration Mode• Pr

Pagina 7

GB - 1442PHQ---NGuide for the ownerWhen installation and tests are completed explain the Operationand Maintenance Manual to the owner, with particular

Pagina 8

Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1The manufacturer reserves the right to change any product specifications without notic

Pagina 9

42PHQ---NSplit system “Hi-Wall” indoor unitGB - 1ENGLISHFor operation and maintenance instructions of this unit, as well as installationinstructions o

Pagina 10

42PHQ---NGB - 2Dimensions and weightTable I: Nominal data• Unit is not suitable for operation in laundry premises.• For sizing of power supply wires

Pagina 11

42PHQ---NGB - 3ENGLISHaMinimum clearances (mm)a ObstacleTable lIl: Material suppliedThe following installation accessories are supplied with unit. Use

Pagina 12

GB - 442PHQ---NUnit installationRead this instruction manual thoroughly before starting theinstallation.• This unit complies with low-voltage (EEC/73/

Pagina 13 - Electrical connection

GB - 542PHQ---NENGLISHExposure to direct sunshine, when unit is operating in coolingmode; always use shutters or shades.Positions too close to heating

Pagina 14

GB - 642PHQ---NMarking the wall penetration for theconnection pipingRear piping• It is best for the piping to go through the wall behind the unit, sot

Pagina 15 - Guide for the owner

GB - 742PHQ---NENGLISHInstallationRouting the drain hose and refrigerantpiping• Tie together the refrigerant pipe, the drain hose, and theelectrical c

Pagina 16 - 42PHQ---N (IOM)

GB - 842PHQ---NRefer to the outdoor unit installation manual for tube sizing,and limitations (slope, length, number of bends allowed,refrigerant charg

Comentarios a estos manuales