Installation Instructions
50HS-900---006
50LQ-900---001
NOTE: Read all instructions before beginning this installation.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment
can be hazardous due to system pressures and electrical com-
ponents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
When working on air-conditioning equipment, observe pre-
cautions in the literature, tags, and labels attached to the unit,
and other safety precautions that may apply.
Before performing service or maintenance operations on
unit, turn off main power switch to unit. Electrical shock
can cause personal injury or death. TAG DISCON-
NECT SWITCH WITH A SUITABLE WARNING
LABEL.
INTRODUCTION
Accessory outdoor thermostats provide staged control of
multi-stage accessory electric heaters. Each accessory out-
door thermostat energizes a particular stage of heat (in ad-
dition to the stages provided by the indoor thermostat) in
response to dropping ambient temperature. See Table 1 for
accessory outdoor thermostat kit contents.
The accessory supplemental heat relay for 50QQ,YX heat
pumps is required only when 2 outdoor thermostats are used
with 3-stage heaters. It is automatically energized by the manu-
ally operated supplemental heat switch in the indoor ther-
mostat subbase. The thermostat locks out the compressor and
the relay bypasses one outdoor thermostat for electric heater
operation during heat pump shutdown, when appropriate. When
one outdoor thermostat is used, a supplemental heat relay is
not required. The supplemental heat switch in the indoor ther-
mostat subbase bypasses outdoor thermostat, locks out the
compressor, and activates electric heater.
Mount supplemental heat relay in low-voltage section of
control box with sheet metal screw provided.
The 50HS, 50HX, 50SS, and 50SX units have single-
stage electric heaters. Only one accessory outdoor thermo-
stat and no supplemental heat relays are required.
Table 1 Accessory Outdoor Thermostat
Kit Contents
ITEM ITEM PART NO. QTY
Outdoor Thermostat HH22QA040 1
Thermostat Setting Label 50MQ501072 1
2 in. Flex. Grommet Strip 50LQ500282 1
Phillips Head Screws
(no. 8 screw,
3
8
in.)
AL56AU165 2
Wire Ties HY76TB130 2
Red Wire 48 in., 16 gage 1
Blue Wire 48 in., 16 gage 1
INSTALLATION
1. Mount Thermostat:
Models 50EE, 50QQ, and 50YX:
Mount outdoor thermostat(s) on unit center post with screws
provided (see Fig. 1).
Models 50NE and 50NQ:
Mount outdoor thermostat(s) on bottom panel of control
box with screws provided (see Fig. 1). Insert adjusting
shaft through holes provided in the bottom of the control
panel.
Model 50HS, 50HX, 50SS, and 50SX:
Mount outdoor thermostat in low-voltage splice box with
screws provided. (See Fig. 1). Insert adjusting shaft through
holes provided in the bottom of the control panel.
THERMOSTAT
CAPILLARY
CONDENSATE
DRAIN
CENTER
POST
OUTDOOR
THERMOSTAT(S)
UNITS 50EE, 50QQ, AND 50YX
UNITS 50NE AND 50NQ
(TYPICAL 50NE UNIT SHOWN)
Fig. 1 Mounting Outdoor Thermostat
50EE, 50HS, 50HX, 50NE,
50NQ, 50QQ, 50SS, 50SX, 50YX
Accessory Outdoor Thermostat
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1144
Tab 1b5a5a6b
PC 111 Catalog No. 535-047 Printed in U.S.A. Form 50HS-4SI Pg 1 6-94 Replaces: 50N,Q,Y-2SI
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - Installation Instructions

Installation Instructions50HS-900---00650LQ-900---001NOTE: Read all instructions before beginning this installation.SAFETY CONSIDERATIONSInstallation

Pagina 2 - UNITS 50NE AND 50NQ

2. Attach Thermostat Setting Label:Models 50EE, 50HS, 50HX, 50QQ, 50SS, 50SX, and 50YX:Attach label to sheet metal over thermostat adjusting shaft(see

Pagina 3 - Fig. 4 — Heat Pump Wiring

Fig. 3 — Attaching Capillary to Condensate Drain50HS AND 50HX UNITS(SINGLE-STAGE HEATERS)50NQ, 50QQ, AND 50YX(2-STAGE HEATERS)50HS AND 50HX UNITS(2-ST

Pagina 4 - (2-STAGE HEATERS)

Cooling units with single-stage indoor thermostat and multi-stageheating for 3-stage heaters.Cooling units with 2-stage indoor thermostat and 3 stages