HEATING A COOLING
58DHL
Downflow/Horizontal Induced-Combustion Furnaces
Installation, Start-Up and Service Instructions
Sizes 055-115 = ~ —
NOTE: Remove the Energy Guide tag from the furnace
when the installation is complete.
NOTE: This is a highly specialized piece of equipment.
Before beginning the installation, READ THESE
INSTRUCTIONS CAREFULLY AND COMPLETELY.
INTRODUCTION
Before installing the furnace, refer to “Procedure for
Induced-Combustion Furnaces” (packaged with the equip
ment) for information concerning combustion, venting, pip
ing, and other standard installation practices. Further refer
ence is made to the current edition of the National Fuel Gas
Code NFPA No. 54, TIA-54-1984-1/ANSI Z223.1-1984,
Z223.la-1987 and American Gas Association.
The inducedrcombustion vent system of this furnace is
designed to operate at zero or negative pressure at the vent
connector outlet. This furnace, therefore, comphes with the
National Fuel Gas Code (NFPA No. 54, TIA-54-1984-1/
ANSI Z223.1-1984, Z223.1a-1987), Part 7.3.4.b. This furnace
is also Usted by A.G.A. for use with the type B1 gas vent, as
described in the National Fuel Gas Code, Part 7.4.2.
Each furnace is shipped from the factory completely assem
bled with multispeed direct-drive blower and wired ready for
indoor heating installation. AU sizes featxire a blower con
trol center with easy-to-read low-voltage terminal strip to
ensure proper connections.
Table 1—Clearances (In Inches)
Sizes
055
075 thru 115
DOWNFLOW (In Alcove or Closet)
Sides—Single-Wali Vent
1 0
Type-B1 Double-Wall Vent
0
0
Back
0 0
Top
1
1
Front*—Single-Wall Vent
6 6
Type-B1 Double-Wall Vent
3 3
Vent—Single-Wall
6
6
Type-BI Double Wall
1
1
HORIZONTAL (In Alcove)
Sidesf
1 0
Back
0
0
Top—Single-Wall Vent
1
1
Type-BI Double-Wall Vent
0 0
Front*
18 18
Vent—Single-Wall
6
6
Type-BI Double-Wall
1
1
HORIZONTAL (In Closet)
Sidest
1
1
Back
3
3
Top—Single-Wall Vent
2
2
Type-BI Double-Wall Vent
2
2
Front*—Single-Wall Vent
6
6
Type-BI Double-Wall Vent
3 3
Vent—Single-Wall
6
6
Type-BI Double-Wall 1
1
*Provide a 30-in. service clearance in front of thè furnace,
tindicates suppiy or return sides when furnace is in the horizontai posi
tion.
Fig. 1—Downflow
Aæo33
?
iiilil
n
Fig. 2—Horizontai
A88034
The output capacity and any representations of efficiency
for this product are based on standard Department of
Energy test procedures. The installed operation may veiry,
depending on installation, weather, or other factors.
A CAUTION
Do not install furnace in a corrosive or contaminated
atmosphere. Make sure aU combustion and circulating
are requirements hsted in “Procedure for Induced-Com
bustion Furnaces” are adhered to, in addition to all
local codes and ordinances.
Do not use this furnace during construction when adhe
sives, sealers, and/or new carpets are being installed. If
the furnace is required during construction, use clean
outside air for combustion and ventilation. Compounds
of chlorine and flourine when burned with combustion
air form acids which will cause corrosion of the heat
exchangers and metal vent system. Some of these com
pounds are: paneling and dry wall adhesives, paints,
thinners, masonry cleaning materials, and many other
solvents commonly used in the construction process.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book] 1 I 4 PC 101 Catalog No. 565-807 Printed In U.S.A. Form 58DHL-1SI Pg 1 5-88 Replaces: New
Tab 16a 18a
Vista de pagina 0
1 2 3 4 5 6 7 8 9 10

Indice de contenidos

Pagina 1 - Sizes 055-115 = ~ —

HEATING A COOLING58DHLDownflow/Horizontal Induced-Combustion FurnacesInstallation, Start-Up and Service InstructionsSizes 055-115 = ~ —NOTE: Remove

Pagina 2 - Table 4—Opening Dimensions

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obiigations.B°°k

Pagina 3 - A WARNING

Table 2—Dimensions (in inches)SizeA DEVent Conn055BC14^,6127,612”/,64055CC14=/i6127,612’7,64OrSBC1772157a16 4075CCV'k157fc16 4095CCM'k 157s1

Pagina 4 - OF Filters

Fig. 7—Furnace, Plenum, and Base Installed on a Combustible Floor2.3.Cut and frame hole in floor per dimensions in Table 1 of Installation Instructio

Pagina 5 - Fig. 12—Wiring Diagram

hanger bolts (Four each %-in. all-thread rod) cut to desired length, 1 X % flat washer, % lockwasher, and % nut. Dimples are provided for hole locatio

Pagina 6 - A CAUTION

cn1 KUKM)lA-TRANSKOUMKK. t>i'VACV->-IVAC:>n- iNDi CKH MciTOH m>sr-\ o2K-KtL\v HKAi is'; m.uwKH {MHO Si’M s <~ UKLAV CO(ll.!\

Pagina 7 - CONNECTOR

Fig. 13—Amp Draw Check With Ammetercorrespond to that specified on the unit rating plate. Also, check to be sure that the service provided b

Pagina 8

to the outside, or exposed to air currents from warm- or cold-air registers; or to exposure where the natural circulation of the air is

Pagina 9

The ability to properly perform maintenance on this equipment requires certeun mechanical skUls and tools. If you do not possess these, contact your

Pagina 10 - Tab 16a 18a

(4.) Remove metal screw fitting from wire brush to allow insertion into cable, b. Clean each heat exchanger ceU.(1.) Attach variable-speed reversible

Comentarios a estos manuales

Sin comentarios