Carrier 48NET Manual de usuario

Busca en linea o descarga Manual de usuario para Acondicionadores de aire del sistema de división Carrier 48NET. Carrier 48NET Product data Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Product Data
38GVM / 40GVM
Multi---Split High---Wall Ductless Split System
38GVM --- Size 18k, 24k, 30k, 36k and 42k
40GVM --- Size 9k, 12k, and 18k
A12567
38GVM
40GVM
INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38GVM/40GVM ductless inverter driven multi--split system
provides individual comfort control for up to 5 separate zones.
Two, three, four or five space--saving High Wall ductless fan coils
are matched with one outdoor heat pump. The indoor fan coils are
connected to the outdoor unit by refrigerant tubing and wires.
The fan coils are mounted on the wall, near the ceiling. This
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
S Commercial add--on jobs where the existing air
conditioning system cannot be stretched.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors.
Advanced system components incorporate innovative technology
to provide reliable cooling and heating performance at low sound
levels.
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - Product Data

Product Data38GVM / 40GVMMulti---Split High---Wall Ductless Split System38GVM --- Size 18k, 24k, 30k, 36k and 42k40GVM --- Size 9k, 12k, and 18kA12567

Pagina 2

10PHYSICAL DATA -- 40GVMIndoor Unit 40GVM 009 012 018System Voltage 208/230---1---60Control Voltage Low Voltage Pulse DCElectrical Connections Indoor

Pagina 3 - MODEL NUMBER NOMENCLATURE

11APPLICATION DATAUNIT SELECTIONWhen selecting a variable speed system match the system capacityrange to the anticipated load range. Since a variable

Pagina 4 - AHRI* CAPACITY RATINGS

12APPLICATION DATA CONTINUEDOutdoor Unit Model Cooling Capacity (Btu/h) Heating Capacity (Btu/h)38GVM436 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 1 Zon

Pagina 5 - DIMENSIONS -- OUTDOOR

13UNIT MOUNTING (INDOOR)Mounting Bracket – The fan coil units are furnished withmounting bracket to hang the unit.Support – Adequate support must be p

Pagina 6

14DRAIN CONNECTIONSInstall drains to meet the local sanitation codes. If adequate gravitydrainage cannot be provided, a field installed condensate pum

Pagina 7 - CLEARANCES -- INDOOR

15AIR THROW DATAModel NumberApproximate Air Throw ft. (m)Low Medium High Turbo4 0 G V M 0 0 9 --- --- --- 3 18 (5.5) 21 (6.4) 24 (7.3) 27 (8.2)4 0 G V

Pagina 8 - CLEARANCES -- OUTDOOR

16GUIDE SPECIFICATIONSHORIZONTAL DISCHARGE OUTDOOR UNITSSize Range:1--1/2, 2, 2--1/2, 3 and 3--1/2 Ton Nominal Cooling and Heating CapacityCarrier Mod

Pagina 9 - PHYSICAL DATA -- 38GVM

17GUIDE SPECIFICATIONSINDOOR WALL--MOUNTED DUCT--FREE UNITSSize Range: 3/4, 1 and 1--1/2 Ton Nominal Cooling and Heating CapacityCarrier Model Number:

Pagina 10 - PHYSICAL DATA -- 40GVM

18Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231Manufacturer reserves the right to change, at any time, specifications and

Pagina 11 - APPLICATION DATA

2INVERTER TECHNOLOGY -- COMFORTThe inverter driven compressor is designed to run at various inputpower frequencies (Hz) which controls the motor speed

Pagina 12 - APPLICATION DATA CONTINUED

3MODEL NUMBER NOMENCLATUREOUTDOOR UNIT38 GVM 3--- --- ---18Outdoor UnitINDOOR UNIT40 GVM 3--- --- ---009Fan Coil UnitUnit Ty peGVM --- M u l t i H i g

Pagina 13 - REFRIGERANT LINES

4STANDARD FEATURES AND ACCESSORIESEase of InstallationMounting Bracket SLow Voltage Controls SComfort FeaturesMicroprocessor Con trol SWireless Remote

Pagina 14 - SEQUENCE OF OPERATION

5DIMENSIONS -- INDOORHDWA08289Unit SizeWIn. (mm)HIn. (mm)DIn. (mm)Net Operating WeightLbs. (Kg)9k 33.3 (846) 10.7 (272) 7.1 (180) 22.0 (10)12k 33.3 (8

Pagina 15 - ELECTRICAL DATA

6DIMENSIONS -- OUTDOOR (CONTINUED)35.1 (892)37.2 (946)27.6 (700)15.6 (396)13.4 (341)22.0 (560)14.5 (368)Unit: in. (mm)A12553Fig. 4 – 38GVM024/030024 W

Pagina 16 - PART 2 – PRODUCTS

7DIMENSIONS -- OUTDOOR (CONTINUED)3.0(76)17.7 (450)3.9(99)40.0 (1015)43.4 (1103)42.8 (1087)7.5(191)24.8 (631)17.3 (440)15.8 (401)14.3 (362)4.8(121)Uni

Pagina 17

8CLEARANCES -- OUTDOOR11.8 (300)minimumdistance fromwall11.8 (300)minimum spaceon air inlet side24.0 (610)minimum spaceon service valve side78 (2000)m

Pagina 18 - 38/40GVM

9PHYSICAL DATA -- 38GVMOutdoor Unit 38GVM 218 324 430 436 542System Voltage 208/230---1---60Control Voltage Low Voltage Pulse DCRated Cooling Capacity

Comentarios a estos manuales

Sin comentarios