Compressor development
and ecology.
Compressor development
and ecology.
Conventional 2-in-1 scroll
(R407C)
Consists of one inverter-driven
compressor and one fixed-speed
compressor. Each scroll
compressor comprises a fixed
scroll (spiral) and an oscillating
scroll. The oscillating scroll fits
within the fixed scr
oll. Refrigerant
is drawn from the outside of the
meshing spirals and squeezed
towards the centre of the scrolls,
thereby pressurising the refrigerant.
To minimise leakage, the contact
force required between the two
scrolls is considerable and the
scroll surfaces must be ubricated.
At low compressor speeds
lubrication efficiency is reduced,
resulting in increased compressor
wear.
Dual DC twin-rotary
(R410A)
Consists of two inverter-driven
twin-rotary compressors.
A twin-rotary compressor has two
fixed compression chambers.
An off-centre roller orbits each
chamber to squeeze the refrigerant.
The two r
ollers are both mounted
on the same shaft, but are offset
to provide counter balance
to each other. The contact force
required between the roller
and chamber wall is lowered.
This means that smaller bearings
can be used and lubrication
demand is reduced, saving weight
and making this type of compressor
more suited to lowspeed operation.
Benefits of using
R410A refrigerant.
Benefits of using
R410A refrigerant.
Incorporating the energy-
efficient, non-ozone-depleting
R410A refrigerant in air
conditioning systems delivers
multiple benefits:
• zero ozone-depleting
potential.
• significant increase
in energy efficiency.
• reduced pressure loss
for improved performance.
2-in-1 scroll
Standard
92 kg x 1 (100%)
50 l (100%)
(100%)
Compressor
Efficiency
Weight (comparative, %)
V
olume (comparative, %)
Lubrication requirement
DC twin-rotary
20% improved
25.2 kg x 2 (55%)
15 l (30%)
(2.5%) = 1/40
Benefit
Greater energy savings
Lighter
and mor
e compact
Higher reliability
Leading Technologies
Care of the environment
Blend of two
types with similar
boiling points
Approximately same
boiling point
High boiling point
Blend of three
types with
different
boiling points
Degradation
likely
Degradation
unlikely
R410A
R32 R125 R134a
R407C
Comparison of refrigerant
boiling points (liquid and gas)
New Dual DC twin-r
otary
compressors
Lubrificant
indispensable
Oil
Flow of oil
Oil Flow of oil
High
str
ength
AC
fixed speed
compr
essor
AC
inverter
compr
essor
DC
inverter
compressor
DC
inverter
compr
essor
Oil
r
egulating
pipes