42VMC---N
GB - 8
Installation: 42VMC 028N - 036N - 048N
Bracket screws
Anchor screws
Ceiling installation
(42VMC 028N - 048N)
Preparation
The piping connecting the indoor and outdoor units can be
routed in one of two directions, as shown in figure.
If the piping is routed horizontally (direction no.), the pipe
cover at the bottom of the air conditioner must be removed.
If the piping is routed vertically (direction no.), a water pump
must be installed for drainage (supplied separately, by request).
Minimum 100 mm
Installation
To assemble the ceiling bracket, use the 4 mounting strips and
the 8 UNC-10 screws and nuts, as shown in figure.
Fasten the ceiling bracket to the ceiling using the 6 anchor
screws, as shown in figure.
The location of the ceiling bracket should allow a minimum gap
between the indoor unit and nearby walls, as shown on page 2.
Note:
The anchor screws provided are intended for use with concrete
ceilings.
Use fasteners which are appropriate for the type of ceiling
present at the installation site.
Use the template supplied, and drill the 6 fixing holes in the wall.
Use the 6 dowels provided.
Outdoor Sensor
Cable
Refrigerant
Lines
Electrical
Cable
Drainage
Tube
F
A
N
M
O
D
E
900
28
509
1042
Ø 80
513
510
4
5
3
555
533
165
210
360
141
Template mod. 028N - 048N
Frame
Outdoor air intake
Hole for refrigerant pipe