4. Open the liquid line valve (small valve) with an Allen wrench.
5. Open the suction line valve (large valve) with an Allen
wrench.
6. The outdoor unit is supplied with sufficient refrigerant for 26
ft of tubing. Add 0.9 oz of refrigerant and 0.35 oz of oil for
each additional foot of tubing used. If the tubing is shorter
than 26 ft, remove gas from the system through the service
valve into a recycling device.
7. Close the service port caps on the suction line and the liquid
valves.
8. Make sure that the valves are properly opened. Be careful not
to open them more than required as this may damage the
thread.
9. Replace the stem cap. Oil the cap beam and hand tighten the
cap, until resistance is met. Use a suitable wrench to tighten
the cap by an additional 1/2 turn.
Step 8Leak Test
Leak test all fittings with appropriate test equipment.
Step 9Electrical Data and Connections
Refer to Table 4 or 5 for unit electrical information.
Step 10Two-Way Air Conditioner (Optional Accessory)
Console Only
Allows simultaneous air conditioning of adjacent rooms when
installed as a console
1. Prepare a wooden frame with the proper dimensions. (See Fig.
22.)
2. Locate the indoor unit and install its mounting bracket.
3. Before mounting the indoor unit on the wall, open a hole in the
wall to install the wooden frame using the unit as a guide
4. Insert the frame in the wall and fill in any gaps between the
frame and the wall hole with an appropriate material.
Fig. 13Connecting Wire Ends to Terminal Block
A01210
Po
wer
Outdoor
Fan
Indoor
Control
Display
Step
Motor
Heat
TH1
TH2
TH3
1
3
4
7
5
10
2
8
8
9
STEP
MOTOR
DISPLAY
TH3
TH2
TH1
HEAT
POWER
INDOOR
FAN
OUTDOOR
CONTROL
7
1
3
4
510
DISPLAY
TH3
TH2
TH1
HEAT
2
6
8
9
STEP
MOTOR
Fig. 14Outdoor Unit Installation Guideline
A01158
1
2
3
4
5
6
7
1
2
3
4
5
6
7
PLUG TO CONNECT
WITH OUTDOOR
SENSOR CABLE (TH3)
INTER-UNIT
ELECTRIC CABLE
CLAMP
ABSORPTION
CUSHION X4
Fig. 15Wiring Diagram Schematic
A01159
1
2
3
4
5
6
7
8
9
10
1
3
4
5
7
10
2
6
8
9
HIGH SPEED
HEAT PUMP
MEDIUM
SPEED
LOW SPEED
COMPRESSOR
*HEATER HDE
PHASE
NEUTRAL
BLACK
~ BROWN
YELLOW
GRAY/ORANGE
RED
~ BLUE
WHITE
GREEN/YELLOW
INDOOR UNIT
OUTDOOR UNIT
OUTDOOR SENSOR
CABLE (TH3)
* FOR H/P MODELS
OUTDOOR
INDOOR
DISCONNECT SWITCHES
(NOT SUPPLIED)
POWER
BROWN
POWER
BLUE
GROUND
GR/YEL
2
6
8