HEAT PUMPS PAY THEIR
OWN WAY
Heat pump models are available at a nominal
additional cost. In many locales, the payback is
realized in just a few months. Cost and payback
details are provided on the next page.
SPECIAL FEATURES
Two-Stage Thermostat:
The indoor thermostat senses the indoor temperature
and automatically turns on the electric heat to warm
the room quickly. After the desired temperature
conditions have been satisfied, the thermostat
automatically switches to heat pump mode. If
compressorfailureoccurs,thethermostatwillprovide
backup electric heat automatically.
Outdoor Thermostat:
During the heating cycle, the outdoor thermostat
senses outdoor coil temperature. It switches the unit
to electric heat mode when the outdoor coil
temperature is 28˚ F (--2.2˚ C) or below for one
minute. Thethermostatswitches theunitback toheat
pump mode when the outdoor coil temperature rises
above40˚ F (4.4˚ C)fortenminutes,which isenough
to provide heat to meet demand. The entire operation
is completely automatic.
Reversing Valve:
The reversing valve provides quiet refrigerant flow
when energized in heating mode. The valve controls
the direction of refrigerant flow for both heating and
cooling functions and remains en
erg
ized as long as
the controls are in the heat position. When the
cooling controls are activated, the valve automatically
reverses to the cooling position.
Manual Compressor Override Configuration:
HOW THE HEAT PUMP WORKS
A07553
In Hot Weather:
A07553
In Cool Weather:
When the outdoor coil temperature is above 28˚ F
(--2.2˚ C), the heat pump draws heat from outdoorair
and uses it toheat indoorair. Sinceheat istransferred
and not produced, Gree’s heat pump uses less
electricity and reduces energy costs significantly.
A07554
In Sub-Freezing Weather:
When the outdoor coil temperature falls below 28˚ F
(--2.2˚ C) for one minute, the unit automatically
switchesonabuilt--inelectricheater.Thecompressor
stopsand theindoorfancirculateswarm airproduced
bytheheater.Whentheoutdoorcoiltemperaturerises
above 40˚ F (4.4˚ C) for ten minutes, heat pump
operation resumes automatically.
GA
Gree’s PTAC units provide indoor comfort in the same
manner as conventional air conditioners, removing
heat and humidity fromindoor air. The heat and
humidity is released to the outdoors. Gree’s high
efficiency design saves energy and reduces cooling
costs.
This configuration dip switch completely locks out
the compressor. See Owners Manual for more
details.Note that the compressor and heater do not
operate at the same time, thus conserving energy.
APPLICATIONS
Hotels and motels
Nursing homes and assisted living care
centers
Offices
Apartments
Single--family dwellings
Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW
CONSTRUCTION
Design Flexibility for the Architect/Engineer
Whisper--quiet performance, indoors and out
No bulky duct system
No separate equipment room
No water towers or additional cooling
equipment
No complex match--up of different HVAC
components
Less sensitivity to building orientation (sun,
wind, shade)
Optional architectural grille to permit custom
exterior appearance
I nitial Cost Savings for the Buildin
g Owner
N
o expensive component HVAC system
purchase
No equipment room or maintenance
engineering staff
Two--part delivery to minimize on--site
damage
Weather--protected wall sleeve that goes in
place during construction; chassis that slides
in place after construction
No seasonal changeover required for cooling
or heating -- units are self--contained comfort
systems
Lower Operating Costs and Reliable Comfort
for The Occupant
Heat pump models offer substantial savings
over models with conventional electric
resistance heaters
Individual units allow tenants to choose the
degree of comfort and operating economy.
Rapi
d servicing reduces downtime: complete
chassis can be replaced in minutes without
disrupting other occupants.
Each unit operates independently of other
units in the building. No dependency by
building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve,
your options include:
Replace the existing wall sleeve with the
the polymer wall sleeve. See accessory sleeve
section for selecting the correct sleeve for
your application.
NOTE: in most cases, when replacing the
wall sleeve, the exterior grille must also be
replaced.
Use an existing sleeve and exterior grille. The
Gree GA series PTAC will fit into:
Friedrich T series and ZoneAire wall
sleeves, with a required wa
ll slee
ve
extension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
GA
Whether you are designing a new structure or
replacing packaged terminal air conditioning units in
an existing building, Gree GA Series will meet your
needs.
The Gree GA series Packaged Terminal Air
Conditioning (PTAC) unit is designed to meet the
needs of the architect, engineer, and contractor. For
unit installation, Gree’s expert support network will
assist in all applicable aspects of the construction
project, from preparing a budget to start-up.
4
The following major competitors’ wall
sleeves/grilles: Carrier, GE, Amana,
Trane, Friedrich and Bryant, and NO
accessory retrofit kit is required.