Carrier 52M Performance Series Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
Always look for these symbols, the air conditioning
industry seals of certified performance, efficiency
p y
3
QUICK SPECIFICATIONS
COOLING & ELECTRIC HEAT
MODEL NUMBER
Cooling
Capacity
BTUH
EER
Electrical
Heating Capacity
Voltage
Reverse
Cycle
Heat
(BTUH)
COP
Voltage
Range
Standard Indoor CFM (Dry / Wet) COOLING
Approx. Ship
Weight
lb
Low
Med
High AMPS WATTS
15 or 20 Amp cord
only*
---
---
187 --- 253
260/240 3.0/2.8 620/640 121
3.9/3.7 770/800 128
5.5/5.1 1120/1120 137
7.5/6.7 1510/1530 143
2.4 640 121
3.7 800 128
4.8 1120 137
5.9 1530 143
280/260 300/280
---
--- 260/240
280/260
300/280
15, 20 or 30 Amp
cord only*
---
---
270/250 290/270
310/290
---
---
300/280 320/300 340/320
15 or 20 Amp cord
only*
---
---
239---292
260/240 280/260 300/280
---
--- 260/240
280/260
300/280
15, 20 or 30 Amp
cord.*
---
--- 270/250
290/270 310/290
---
--- 300/280
320/300
340/320
HEAT PUMPS
Model No.
Cooling
Capacity
BTUH
EER
Electrical
Heating Capacity
Reverse Cycle
Heat
BTUH
COP
Voltage
Range
Standard Indoor CFM (Dry / Wet) COOLING
Approx.
Ship
Weight
lb
Low Med High AMPS
WATTS
15 or 20 Amp cord
only*
187---253 6100/6300 3.4/3.4
7900/8100 3.3/3.3
10500/10700 3.1.3.1
13800 2.9
6300 3.4
8100 3.3
10700 3.1
13800 2.9
3.0/2.8 620/640 121
3.9/3.7 770/800 128
5.3 / 5.1 1120/1120 137
6.7 1530 143
2.4 640 121
3.7 800 128
4.8 1120 137
5.9 1530 143
260/240 280/260 300/280
187---253 260/240 280/260
300/280
15, 20 or 30 Amp
cord only*
187---253
270/250
290/270 310/290
15, 20 or 30 Amp
cord only*
207---253
300/280 320/300
340/320
15 or 20 Amp cord
only*
239---292 260/240 280/260 300/280
239---292 260/240 280/260
300/280
15, 20 or 30 Amp
cord.*
239---292 270/250
290/270 310/290
15, 20 or 30 Amp
cord.*
239---292
300/280 320/300
340/320
* See Power Cord Selection chart below for heating capacity rating. Using 30 Amp cords on U07 and U09 models could result in damage to unit.
Dry = Heat Mode Indoor Standard CFM @ 230 or 265 volt / Wet = Cool Mode Indoor Standard CFM @ 230 or 265 volt
POWER CORD SELECTION:
Model No. Voltage Receptacle Type Heating (Btuh)
Heater (Kw)
Input Power
(WH)
Current
(Amps)
Branch Circuit
Full Amps
PWRCORD--- 230V--- 15A
208/230V
15 AMP /250V 5500/6800 1.635/2.0
1643/2047
7.9/8.9 15
PWRCORD--- 230V--- 20A
20 AMP / 250V
8300/10200
2.453/3.0
2496/3036
12.2/13.2
20
PWRCORD--- 230V--- 30A
30 AMP / 250V 13900/17000 4.089/5.0
4118/5037
20.5/21.5
30
PWRCORD--- 265V--- 15A
265V
15 AMP / 277V
6800 2.0
2120 8.9
15
PWRCORD--- 265V--- 20A
20 AMP / 277V
10200
3.0 3127 13.2 20
PWRCORD---265V--- 20A
30 AMP / 277V 17000
5.0
5035 21.5
30
NOTE: In compliance with UL, and the National Electrical Code, 265V units installed with a power cord require the use use of a 265V electrical subbase.
GA
Gree’s GA aeries PTACs are not individually equipped with a power cord, so one must be ordered separately based on the voltage and amperage of your electrical circuit.
If the unit is to be plugged into a receptacle, then a line cord connection kit needs to be selected. If it will be permanently connected, a hardwire connection must be used.
and capacity.
PTAC-GAE07AB-D 7600/7700 12.2/12
PTAC-GAE09AB-D 208/ 8800/9000 11.4/11.3
PTAC-GAE12AB-D 230V 11800/12000 10.5/10.7
PTAC-GAE15AB-D 14600/15000 9.7/9.8
PTAC-GAE07AB-P 7700 12
PTAC-GAE09AB-P 9000 11.3
PTAC-GAE12AB-P 12000 10.7
PTAC-GAE15AB-P 15000 9.8
265V
PTAC-GAA07AB-D 7600/7700 12.2/12
PTAC-GAA09AB-D 8800/9000 11.4/11.3
PTAC-GAA12AB-D 11800/12000 10.5/10.7
PTAC-GAA15AB-D 15000 9.8
PTAC-GAA07AB-P 7700 12
PTAC-GAA09AB-P 9000 11.3
PTAC-GAA12AB-P 12000 10.7
PTAC-GAA15AB-P 15000 9.8
265V
208/
230V
Voltage
Vista de pagina 2
1 2 3 4 5 6 7 8 ... 43 44

Comentarios a estos manuales

Sin comentarios