30
PERFORMANCE AND ELECTRICAL DATA
MODEL 52SE (265 V)
L
EGEND
EER —
Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310/380-93.
†Electric resistance heater power and fan motor power.
**All 265-v units require either the Accessory Hard-Wire Kit or the Accessory Cord-
Connected Kit for installation. Use of the Accessory Cord-Connected Kit requires
the installation of the Subbase along with a field-supplied receptacle. Receptacle
configurations of the Accessory Cord-Connected Kit are shown at right.
RECEPTACLES AND FUSE TYPES
LEGEND
MODEL
NUMBER
CAPACITY* (Btuh)
EER
HEATER
kW
VOLT
RANGE
COOLING
(Amps)
HEATING†
(Amps)
COOLING
(Watts)
HEATING
(Watts)
Cooling Heating
52SED207---4 7,100 7,800 11.0 2.3
292-239
2.7 9.3 645 2435
52SED307---4 7,100 11,600 11.0 3.4 2.7 13.4 645 3535
52SEE209---4 9,100 7,800 9.5 2.3 3.8 9.4 958 2435
52SEE309---4 9,100 11,600 9.5 3.4 3.8 13.5 958 3535
52SEC212---4 12,000 7,800 9.2 2.3 5.2 9.5 1304 2508
52SEC312---4 12,000 11,600 9.2 3.4 5.2 13.6 1304 3608
52SEC512---4 12,000 17,000 9.2 5.0 5.2 19.7 1304 5208
52SEC214---4 13,700 7,800 9.0 2.3 5.9 9.5 1522 2505
52SEC314---4 13,700 11,600 9.0 3.4 5.9 13.6 1522 3605
52SEC514---4 13,700 17,000 9.0 5.0 5.9 19.7 1522 5205
MODEL
NUMBER
POWER
FACTOR
%
FAN MOTOR
MAX.
FUSE
SIZE
(Amps)
MIN.
CIRCUIT
AMPS
RECEP-
TAC L E
TYPE**
R-22
CHARGE
(oz)
DEHUMIDIFICA-
TION (Pints/Hr)
APPROX.
CHASSIS
SHIP WT (lb)
Hp
Full
Load
Amps
Indoor
CFM
HI/LO
52SED207---4
94
1
/
15
0.56 280/200
15 11.5 A
23 1.3 125
52SED307---4 20 16.6 B
52SEE209---4
95
1
/
8
0.7 350/300
15 11.6 A
27 2.1 120
52SEE309---4 20 16.7 B
52SEC212---4
99
1
/
6
0.8 380/310
15 11.7 A
36 3.4 12952SEC312---4 20 16.8 B
52SEC512---4 25 24.8 C
52SEC214---4
98
1
/
8
0.7 350/300
15 11.7 A
35 4.7 13052SEC314---4 20 16.8 B
52SEC514---4 25 24.4 C
UNIT NAMEPLATE VOLTAGE 265
OUTLET RATED VOLTS/AMPS 277/15 277/20 277/30
OUTLET BLADE CONFIGURATION
ABC
FEMALE RECEPTACLE MANUFACTURER’S
PA R T N O.
Arrow-Hart 5302 7621 5795N
Hubbell ——9315
Eagle 834B-BOX 834B-BOX —
NEMA CONFIGURATION 7-15R 7-20R 7-30R
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
15 20 30
HEATER (KILOWATTS) 2.3 3.4 5.0
HACR —
Heating, Air Conditioning, and Refrigeration
NEMA —
National Electrical Manufacturers Association
PRODUCT DATA (cont)