Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-NRH-A Manual de instrucciones Pagina 80

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 79
80
Single-Stage
Equipment Control Module
Furnace Air Conditioner
Heat Stage 2 O/B W2
Heat Stage 1 W/W1 W1
N/A Y1 / W2 Y1
Cool Stage 1 Y/Y2 Y/Y2 Y
Fan G G
24VAC Hot Heating Rh R
24VAC Hot Cooling Rc R
Dry Contact 1 D1
Dry Contact 2 D2
DHUM
24VAC Common C
COM
C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
A08160
Fig. 36 -- Single-- stage Furnace with Air Conditioner and Split Power
* Indicates connection may not be required/available.
NOTE: Rc/Rh jumper is cut o n the Equipment Control Module.
Vista de pagina 79
1 2 ... 75 76 77 78 79 80 81 82 83 84

Comentarios a estos manuales

Sin comentarios