Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
14
Note: User Interface selections override furnace board dipswitch settings
Furnace Generated Fault Descriptions cntd.
Flash
Code
Fault
Description User Interface Display
Action
32 Low-Heat Pressure Switch
Did Not Close Or Reopened
LOW PRESSURE SWITCH OPEN in
fault history
No display on main screen
This fault may show up
in the fault history of
condensing furnaces
due to unprimed trap
at start up, wind, or
other factors
temporarily affecting
the vent system. It is
not necessarily a
system problem. If
troubleshooting does
not determine a
problem, turn on low
heat rise in furnace set
up to boost inducer
airflow by 15%.
33 Limit Circuit Fault LIMIT CIRCUIT FAULT in fault history
SYSTEM MALFUNCTION on main
screen
34 Ignition Proving Failure IGNITION FAULT in fault history
No display on main screen
See Service / Status
Code label in furnace
or furnace
troubleshooting guide
41 Blower Motor Fault BLOWER FAULT in fault history
CRITICAL MALFUNCTION on main
screen
41 codes may show up
in fault history, but if
system is operating
properly, this can be
ignored.
42 Inducer Motor Fault (VS
Inducers Only)
INDUCER FAULT in fault history
No display on main screen
43 Low-Heat Pressure Switch
Open While High-Heat
Pressure Switch Closed
LPS OPEN HPS CLOSED in fault history
No display on main screen
45 Control Circuitry Lockout CONTROL LOCKOUT in fault history
CRITICAL MALFUNCTION on main
screen
See Service / Status
Code label in furnace
or furnace
troubleshooting guide
Comentarios a estos manuales