Carrier 38TDB Guía para resolver problemas Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
2
User Interface Software Identification
This guide covers Infinity and Evolution zoning and non-zoning systems with versions CESR131339-03, -
05, -06, -08, -10, and -12 software (versions 7, 9, and 11 were not put into production) . The model
numbers included are listed below:
Carrier: SYSTXCCUIZ01, SYSTXCCUIZ01-A, SYSTXCCUID01, SYSTXCCUID01-A
Bryant: SYSTXBBUIZ01, SYSTXBBUIZ01-A , SYSTXBBUID01, SYSTXBBUID01-A
There are two ways to determine the software version: enter the Service menus with a 10 second push of
the Advance button, or cycle power to the User Interface. When power is re-applied, the User Interface
will re-establish communications with the equipment and display the software version as shown below:
The first Service menu screen will show the software version near the bottom of the screen. Infinity and
Evolution systems are designed to alert the equipment owner of a potential system problem, and help
guide the servicer in determining a system problem. Two types of alerts can pop up on the User Interface
screen when a system problem or potential system problem exists. These alerts are described below.
Critical Malfunctions (software versions 3,5,6,8 only)
Certain system problems will result in the message “CRITICAL MALFUNCTION CALL TECHNICIAN”.
A critical malfunction is a system problem that will result in no system operation, and must be
addressed immediately. It usually means there is a problem related to the indoor unit blower motor.
The message will be displayed as shown in the figure below. The following will cause this message:
Fan Coil generated Critical Malfunctions:
Code 44 – Motor Communication Fault
Code 41 – Blower Motor Fault
Furnace generated Critical Malfunctions:
Code 15 – Blower Motor Lockout
Code 41 – Blower Motor Fault
FAN: AUTO
CALL TECHNICIAN
OUTSIDE: 94
o
ALERT !
CRITICAL MALFUNCTION
JOE'S HVAC SERVICE
(317) 555-1234
The mode LEDs will
alternately flash red
on/blue off for 0.5 seconds,
then blue on/red off for 0.5
seconds.
ESTABLISHING
COMMUNICATIONS
WITH EQUIPMENT
PLEASE WAIT
WORKING
SOFTWARE VERSION
CESR131339-06