3
Installation, start-up and servicing of equipment can be
hazardous if certain factors particular to the installation are
not considered: operating pressures, presence of electrical
components and voltages and the installation site (elevated
plinths and built-up up structures).
Only properly qualified installation engineers and highly
qualified installers and technicians, fully trained for the
product, are authorised to install and start-up the equipment
safely.
During all servicing operations all instructions and recommen-
dations which appear in the installation and service instruc-
tions for the product, as well as on tags and labels fixed to
the equipment and components and accompanying parts
supplied separately, must be read, understood and followed.
• Apply all standard safety codes and practices.
• Wear safety glasses and gloves.
• Use the proper tools to move heavy objects. Move
units carefully and set them down gently.
Only personnel qualified in accordance with IEC (Inter-
national Electrotechnical Commission) recommendations
may be permitted access to electrical components. It is
particularly recommended that all sources of electricity to
the unit be shut off before any work is begun. Shut off the
main power supply at the main circuit breaker or isolator.
IMPORTANT: This equipment conforms to all applicable
codes regarding electromagnetic compatibility.
Pro-Dialog is an electronic control system to regulate 38RBS
condensing units. These units have one or two refrigerant
circuits.
Pro-Dialog control must be completed either by a thermostat
or by two temperature sensors (room and supply air).
Control by thermostat (via contacts) is the default operating
mode and called remote mode.
For two-stage cooling units the Carrier 33CS thermostat
can be used.
The thermostat (programmable or non programmable)
ensures the start-up of the indoor fan and controls the unit
cooling stages (two to four stages, depending on the unit
size). This thermostat can also allow control of the electric
heater.
A second control type with temperature sensors is also
possible. Selection and parameter setting of this control
type are only available via the Carrier Pro-Dialog+ HMI
user interface. As an option Carrier offers the complete
equipment required for this control type.
To use this control type, three operating modes are available:
• Local on - continuous temperature control.
• Loc/Prog on - temperature control only in the occupancy
ranges defined by the user via the local interface.
• CCN bus - temperature control, based on the commands
from the Carrier Comfort Network (CCN).
Temperature sensor control permits:
• room temperature control at the desired setpoint,
• ensuring a minimum supply air temperature.
Independent of the selected control type, Pro-Dialog:
• ensures user comfort,
• controls the compressors based on the cooling load,
• controls the fans to optimise operation of each
refrigerant circuit,
• ensures unit protection.
The heating stages are not controlled by Pro-Dialog.
In this manual, the refrigerant circuits are called circuit A
and circuit B. The compressors in circuit A are labelled A1,
A2 and A3. Those in circuit B are B1 and B2.
The following abbreviations are used frequently:
CCN Carrier Comfort Network
DGT Discharge gas temperature
LED Light Emitting Diode
LEN Internal communication bus linking the main
board to the slave boards
OAT Outdoor air temperature
SCT Saturated condensing temperature
SST Saturated suction temperature
Comentarios a estos manuales