Carrier XRV Especificaciones Pagina 144

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 143
144
206 208207
L2
T2
A1
A2
L3
T3
L1
T1
13
14
225F
231G
13
A1
CONTACTORS
PRECHARGE
K1A
T2
L2
A2
T3
L3
K1B
T1
L1
14
231H
225C
K1C
T2
L2
A1
L3
A2
T3
L1
13
T1
14
L2
L1
L3
VFD POWER MODULE
COMBINED I/O
A1
A12
5
7
6
3
4
TEMPSW INV
TEMPSW RCT
PRECHARGE FB
SHUNT TRIP
SW 24V
1
2
TB7
CNTRL PWR
PRECHARGE OUT
FU5
FU4
FU6
300A
500V
RESISTORS
INPUT INDUCTOR
20
MAIN CIRCUIT
PRECHARGE
203
R4
2
FU7
1
200
FILTER CAP ASSY
46 uF ea
4x 140J
R1
R2
50k , 100W
R3
2
2
6
R5
2
204
1
FU8
2
1
TS1
2
7
1
4
8
9
5
R6
205
202
FU9
M5
2
1
2
M4
1
ST
1
IND1
1
2
3
214
213
R
CB1
TS
212
1
M3
1
M2
2
FU3
FU1
FU2
1A/600V
CLASS 'CC'
1
2
1
2
H*
X2
FU10
1
DO 2 COM
DO 2 NC
LINE
5
3
DO 3 NC
DO 3 COM
DO 4 COM
DO 3 NO
DO 4 NC
8
9
7
5
6
2
4
3
TB1
TB5
DO 4 NO 1
(3kVA, 120V, 25A)
CONTROL TRANSFORMER
INPUT FIELD WIRING REF.
GND
L1
L3
L2
H1
T1
X1
10A
20A
FU11
W
V
U
201
229
228
600V
20A
600V
20A
600V
20A
217
216
215
225A,B,C,D
224B
224A
225D
225A
233
X1
4
3
1
2
225C
231H
231C
230C
231D
230D
231E
230E
231J
230J
230C,D
230E,J
231C,D
231E,J
225B
231A
263A,B
233
227A
229
232
225E
231F
226B
263A
232
D722A722 227E
2V
L1
L2
L3
DO 2 NO
SYNC
1 uF
AO 1-
AO 2+
2
3
TB9
221B
(LL1) PP/1C-22
NOTE: MOTOR OVERLOAD IS
T1/T6
T3/T5
EXTERNAL- REF. ONLY
T2/T4
MOTOR
M1
GND
FACTORY PRE-SET.
DO NOT ADJUST.
TRIP ALARM10
TOWER FAN LOW
TOWER FAN LOW
TRIP ALARM
TOWER FAN HIGH
TOWER FAN HIGH
5
6
9
8
7
EVAP PUMP
TB2
EVAP PUMP
COND PUMP
COND PUMP
2
1
4
3
SPARE SAFETY
ICE BUILD
ICE BUILD
REMOTE START
REMOTE START
20
22
21
24
23
NOT USED
NOT USED
4-20mA PRESS REF-
4-20mA PRESS REF+
SPARE SAFETY
15
18
17
16
19
(LL2) PP/1C-23
(PE) PP/CHASIS
BLACK
BROWN
RED
ORANGE
GREEN
WHITE
PP50
PRESSURE
SW
PP43
TB1
OIL
HIGH
INT/LOCK
PP51
PP17
OIL HEATER
CONTACTOR
(OS1) PP/2C-21
(OS2) PP/2C-22
(OS3) PP/2C-23
RED
BLACK
BLACK
YELLOW
OIL PUMP
CONTACTOR
METERS W/SWITCH
(OPTIONAL)
SW1
AMMETERVOLTMETER
VM1
+
L2
L3L1
A1A2B2 B1
AM1
+
258
(3 POLE, 15A)
L1
L3
L2
T1
T3
T2
CONTROL BREAKER
CB2
218
219
220
H1-H3: 380VAC
H1-H2: 346VAC
*T1 INPUT (50/60Hz)
H1-H6: 480VAC
H1-H5: 460VAC
H1-H4: 400-415VAC
222B
223
(COM) PPB
(NEG) PPC
(POS) PPA
A32
RS485
4
6
5
1
2
3
256
COM
GND
SHIELD
RED
254
255
TERM
A
B
BLACK
WHITE
COMM
7AO 4+
--
AO 2- 4
AO 1+ 1
11DO 5 COM
DO 5 NC 12
DO 6 NO
DO 6 COM
DO 6 NC
DO 5 NO
DO 7 NO
DO 7 COM
DO 7 NC
7
8
9
10
4
5
6
TB2
BREAKER
TB4
-
DI 5
-
6
AO 4- 8
2DI COM 1
DI 3
DI 4
DI 2
DI 24V+
DI 1
GATEKILL +
GATEKILL -
6
8
7
9
5
4
3
D1 24V-
TB3
1
257
260
259
261
263B
262
244
245
246
249
248
247
251
252
253
250
234
235
236
237
238
239
242
243
240
241
231A,H
( MECHANICAL JUMPER)
Fig. 58 — 19XRV 900A and 1200A Chiller VFD Schematic
a19-2019