Chapter 3 111
Pass/Fail Limit (Specification) Descriptions
3. RXA Audio Response Dev from
−
6 dB/oct R2 (dB)
3. RXA Audio Response Dev from −6 dB/oct R2
(dB)
This sets the pass/fail limits used in TEST_06 - TXA Audio Frequency
Response for the receiver’s audio output circuitry, when its audio
response is tested against the standard 6 dB/octave de-emphasis curve.
The audio response should not deviate beyond the pass/fail limits in the
regions of 300 to 400 Hz and 2400 to 3000 Hz. Upper and lower limits
must be entered in dB.
Pass/fail limits are determined by using any applicable standard, such
as:
• EIA/TIA Standard: Voice Audio Frequency Response
Example
If your receivers are normally used with a handset or a line, and the
audio response should not deviate more than +1 to
−6 dB over the
frequency range of 300 to 400 Hz and 2400 to 3000 Hz, enter
−6 as the
Lower Limit and 1 as the Upper Limit.