64 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_27 - CPA Hook Flash
TEST_27 - CPA Hook Flash
Description
This test verifies that the correct hook-flash number (3 digits) is
correctly sent by the cellular radio.
The test works as follows:
1. A voice channel is established.
2. The operator is prompted to dial a 3-digit number and press the
SEND key on the MSUT.
3. If the channel is a wide voice channel, the test detects the resulting
signaling tone from the MSUT and sends a “send-called-address”
order to the MSUT on the Forward Voice Channel (FVC). This step
does not occur on narrow voice channels.
4. The test receives the hook-flash number from the MSUT on the
Reverse Voice Channel and displays it. (The number is not compared
to a specific value or number.)
Pass/Fail Limits Used
• None
Parameters Used
• 1. CPA Control Channel [1-799 or 991 -1023]
• 2. CPA DSAT Vector
• 3. CPA Enter Ph# [0=If Needed,1=Always,Here]
• 4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
• 5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail]
• 6. CPA SAT Tone (Hz)
• 22. RX RF Level for Signaling (dBm)
• 49. TXA TS Atten for Signaling [0, 20, 40] (dB)