Pass/Fail Limit (Specification) Descriptions
40. TXD Closed Loop Power Control Range (dB)
40. TXD Closed Loop Power Control Range
(dB)
This sets the pass/fail limits for closed loop power control. Only the
lower limit is used. The value must be entered in dB.
Pass/fail limits are determined by using any applicable standard such
as:
EIA/TIA Standard: Range of Closed Loop Power Control
Example
If you desire the closed loop power control range to be at least ±24 dB
around the open loop estimate, enter 24 as the lower limit.