Chapter 2 47
Test Descriptions
TEST_19 - RXA FVC Order Message Error Rate
TEST_19 - RXA FVC Order Message Error Rate
Description
This test simulates a Forward Voice Channel (FVC) order message
being sent from a cell site to the cellular radio and measures the Order
Message Error Rate.
The test works as follows:
• A Forward Voice Channel (FVC) audit message is sent 100 times and
the number of acknowledgments from the MSUT is counted.
• The RF level is set by parameter 25. RXA FVC Message Error Rate
RF Level (dBm).
• If the MSUT misses 10 acknowledgments in a row the test
terminates.
FVC order message error rate is expressed in %.
This test is not specified by TIA/EIA standards.
Pass/Fail Limits Used
• 9. RXA Order Message Error Rate (OMER) (%)
Parameters Used
• 1. CPA Control Channel [1-799 or 991 -1023]
• 2. CPA DSAT Vector
• 3. CPA Enter Ph# [0=If Needed,1=Always,Here]
• 4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
• 5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail]
• 6. CPA SAT Tone (Hz)
• 22. RX RF Level for Signaling (dBm)
• 25. RXA FVC Message Error Rate RF Level (dBm)
• 49. TXA TS Atten for Signaling [0, 20, 40] (dB)