Test Descriptions
TEST_19 - RXA FVC Order Message Error Rate
TEST_19 - RXA FVC Order Message Error Rate
Description
This test simulates a Forward Voice Channel (FVC) order message
being sent from a cell site to the cellular radio and measures the Order
Message Error Rate.
The test works as follows:
A Forward Voice Channel (FVC) audit message is sent 100 times and
the number of acknowledgments from the MSUT is counted.
The RF level is set by parameter 25. RXA FVC Message Error Rate
RF Level (dBm).
If the MSUT misses 10 acknowledgments in a row the test
terminates.
FVC order message error rate is expressed in %.
This test is not specified by TIA/EIA standards.
Pass/Fail Limits Used
9. RXA Order Message Error Rate (OMER) (%)
Parameters Used
1. CPA Control Channel [1-799 or 991 -1023]
2. CPA DSAT Vector
3. CPA Enter Ph# [0=If Needed,1=Always,Here]
4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail]
6. CPA SAT Tone (Hz)
22. RX RF Level for Signaling (dBm)
25. RXA FVC Message Error Rate RF Level (dBm)
49. TXA TS Atten for Signaling [0, 20, 40] (dB)