18 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_02 - CPA Page
TEST_02 - CPA Page
Description
Initiates a call to the mobile station from the base station. Specifically,
this test does the following:
1. Performs a page to the MSUT
2. Performs 3 of 5 majority voting on the Reverse Control Message
3. Performs BCH (Bose-Chaudhuri-Hocquenghem) error detection and
correction of the Reverse Control Message
4. Tests each section of the page response, bit by bit
5. Sends an Initial-Voice-Channel-Designation order to the MSUT,
directing it to tune to a voice channel obtained from the Channel
Information table. If the channel number from the table has an L,
M, or U suffix, the phone will be directed to a narrow voice channel.
If the channel number has no suffix, the phone will be directed to a
wide voice channel.
6. Sends an ALERT order to the MSUT by way of the Forward Voice
Channel (FVC)
7. Makes a power measurement on the initial voice channel to verify
that the voice channel was obtained. The power measurement result
is not displayed in this test.
Pass/Fail Limits Used
• None
Parameters Used
• 1. CPA Control Channel [1-799 or 991 -1023]
• 2. CPA DSAT Vector
• 3. CPA Enter Ph# [0=If Needed,1=Always,Here]
• 4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
• 5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail]
• 6. CPA SAT Tone (Hz)
• 22. RX RF Level for Signaling (dBm)
• 49. TXA TS Atten for Signaling [0, 20, 40] (dB)
Comentarios a estos manuales