82 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_37 - TXD Minimum Controlled Output Power
TEST_37 - TXD Minimum Controlled Output
Power
Description
This test measures the minimum controlled RF output power of the
mobile station. The minimum controlled output power is the output
power, measured at the mobile station antenna connector, when both
closed loop and open loop power control indicate minimum output.
1. A Service Option 2 (or 9 if parameter 19. RT Rate Set Selection
[0=9600 1=14400] is set to 1) call is attempted, unless a Service
Option 2 call is already connected. If the MSUT has not registered,
the call attempt may be unsuccessful and the error message “Failed
to establish a call in test <>” will be displayed. To correct this
problem, perform the CPD Registration test.
2. The forward channel power is set to -25 dBm.
3. The Test Set’s “call drop” timer is disabled so that when “all down”
power control bits are sent to the MSUT, the call is not dropped by
the Test Set
4. The Test Set is programmed to send continuous “always down”
power control bits at full data rate. This series of power control bits
will decrease the MSUT’s power level from its open loop estimate to
the minimum transmitted output power.
5. A Channel Power measurement is made while the “always down”
power control bits are being sent.
6. The TXD Antenna Gain parameter is retrieved and used to
determine the upper test limit.
7. The following measurement result is printed to the TESTS (IBASIC
Controller) screen:
TXD Min RF Output Power <Channel Power measurement>
Refer to the Agilent 8924C Reference Guide for information about the
Open Loop power control mode, see the Closed Loop Pwr Cntl field
description.
Refer to the Agilent 8924C Reference Guide for information about the
Input Atten field and Hold mode.
Pass/Fail Limits Used
42. TXD Maximum RF Output Power (dBm)
Vista de pagina 81