Parameter Descriptions
20. RT Test at Extreme Settings [0=no 1=yes]
20. RT Test at Extreme Settings [0=no 1=yes]
This parameter is used to activate all of the parameters that set
extreme testing conditions for the MSUT. If this parameter is set to 1
(yes) the following parameters will be used:
Parameter 15. RT High Supply Voltage (Vdc)
Parameter 16. RT Low Supply Voltage (Vdc)
Parameter 28. RXA NAMPS RF Level for SINAD at Extremes (dBm)
Parameter 30. RXA RF Level for SINAD at Extremes (dBm)
The software offers the capability to run certain tests at extreme supply
voltage conditions. Extreme supply voltage conditions are high and low
supply voltages that are used while testing is conducted. In order to use
the extreme testing conditions an GPIB programmable power supply
must be used. This power supply must be interfaced to the test system
through an GPIB interface cable. For more information on the types of
power supplies supported by the software and how to configure the test
system to control the power supply.
See “To Configure a Programmable Power Supply” in the Agilent
83217A Test Software User’s Guide
The following tests can be run at extreme testing conditions.
TEST_03 - TXA Frequency Error
TEST_04 - TXA RF Power Output
TEST_05 - TXA Modulation Deviation Limiting
TEST_18 - RXA SINAD