72 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_32 - CPD Page
TEST_32 - CPD Page
Description
This test makes a CDMA MSUT-terminated (Test Set originated) call as
follows:
1. An analog release is performed if the MSUT is on an analog voice
channel.
2. A CDMA release is performed if the MSUT is on a digital traffic
channel.
3. The MSUT-terminated call is made. The software routine for
obtaining a traffic channel performs the following tasks:
a. Performs a standard CDMA setup for call processing (refer to
CPD Registration).
b. Attempts a CDMA call by sending a command that performs the
remote equivalent of pressing the CALL key.
c. Monitors the Test Set to display a message prompting the
operator to answer the phone when the Test Set call processing
state is alerting.
d. Monitors the Test Set to indicated that the call has connected or
30 seconds has elapsed, whichever occurs first.
4. The following information is printed to the TESTS (IBASIC
Controller) screen:
Page Successful: <Yes or No>
This test provides and indication of the MSUT’s ability to be paged by a
base station originated call and establish a link.
Refer to the Agilent 8924C Reference Guide for information about the
Answer Mode and MS ID fields.
Pass/Fail Limits Used
None