Chapter 2 19
Test Descriptions
TEST_03 - TXA Frequency Error
TEST_03 - TXA Frequency Error
Description
This test measures the difference between the unmodulated carrier
frequency and the assigned carrier frequency. TXA frequency error is
measured on a voice channel with voice modulation off, and SAT
modulation on. This test is performed at the nominal supply voltage.
This test can only be performed at the high and low supply voltage
settings if an GPIB programmable power supply is configured into the
test system and parameter 20. RT Test at Extreme Settings [0=no
1=yes] is set to 1. See “TEST_03 - TXA Frequency Error” on page 19 for
details on configuring an GPIB programmable power supply.
The frequency error is expressed in parts-per-million (ppm).
Pass/Fail Limits Used
• 20. TXA Frequency Error (ppm)
Parameters Used
• 1. CPA Control Channel [1-799 or 991 -1023]
• 2. CPA DSAT Vector
• 3. CPA Enter Ph# [0=If Needed,1=Always,Here]
• 4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
• 5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail] 0
• 6. CPA SAT Tone (Hz)
• 15. RT High Supply Voltage (Vdc)
• 16. RT Low Supply Voltage (Vdc)
• 17. RT Nominal Supply Voltage (Vdc)
• 20. RT Test at Extreme Settings [0=no 1=yes]
• 22. RX RF Level for Signaling (dBm)
• 49. TXA TS Atten for Signaling [0, 20, 40] (dB)
Comentarios a estos manuales